Carrier Access Network Device Axxius 800 Manuale Utente Pagina 323

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 568
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 322
Axxius 800 - Release 2.2 5-223
CLI Commands
show
show (v54)
Use the show (v54) to display current settings for V.54 card.
Syntax: show {v54-addr}
Example: show 3:1
The example shows settings for port 1 (V.54) on slot 3.
> show 3
SLOT 3:
Settings for V35 Port 1:
CTS: Always High
Timing: Source
Rx Clock Inversion: Normal
Tx Clock Inversion: Normal
Data Inversion: Normal
Data Speed: 64K
Data Rate:
V.54 Rx LB: disabled
V.54 Rx Addr: 0
V.54 Test Addr: 0
V.54 Tx Prep count: 15
V.54 Rx Prep count: 15
V.54 Test Pattern: QRSS
V.54 Ignore ACK: OFF
Loopback: None
{v54-addr}
In the form {slot|slot:port}.
slot slot (1-8) location of a V.35/54 card.
port Port number or range.
Vedere la pagina 322